Gas Environment Control Characteristic Analysis for Dynamic Controlled Atmosphere Storage 


Vol. 46,  No. 11, pp. 2064-2071, Nov.  2021
10.7840/kics.2021.46.11.2064


PDF
  Abstract

In this study, we observed the oxygen removal process, which is the initial control process during CA storage, to identify the factors affecting precise gas environment control and to secure theoretical basic design data. For this purpose, the PSA-type nitrogen generator and carbon dioxide scrubber were connected to the airtight storage by exhaust and circulation-type, respectively, and the oxygen removal process was observed from the atmosphere (O2 21%) to 2%. The operating conditions of the CA system were divided into the presence or absence of cooling operation for temperature control, single operation of the nitrogen generator, and combined operation of the nitrogen generator and carbon dioxide scrubber. In addition, the basic data needed for the design was obtained by comparing the results of the gas replacement prediction formula calculation with the experimental results. As a result, the oxygen control time of the low oxygen (5-2%) section according to the operation of the cooling device was 34 and 99 hours, respectively, and the outside air inflow effect by the cooling operation was confirmed. At this time, the carbon dioxide scrubber was predicted to be the same performance as the nitrogen supply of 6 N㎥/h.

  Statistics
Cumulative Counts from November, 2022
Multiple requests among the same browser session are counted as one view. If you mouse over a chart, the values of data points will be shown.


  Cite this article

[IEEE Style]

C. W. Park, D. S. Choi, Y. H. Kim, J. S. Kim, J. Y. Son, "Gas Environment Control Characteristic Analysis for Dynamic Controlled Atmosphere Storage," The Journal of Korean Institute of Communications and Information Sciences, vol. 46, no. 11, pp. 2064-2071, 2021. DOI: 10.7840/kics.2021.46.11.2064.

[ACM Style]

Chun Wan Park, Dong Soo Choi, Yong Hoon Kim, Jin Se Kim, and Jae Yong Son. 2021. Gas Environment Control Characteristic Analysis for Dynamic Controlled Atmosphere Storage. The Journal of Korean Institute of Communications and Information Sciences, 46, 11, (2021), 2064-2071. DOI: 10.7840/kics.2021.46.11.2064.

[KICS Style]

Chun Wan Park, Dong Soo Choi, Yong Hoon Kim, Jin Se Kim, Jae Yong Son, "Gas Environment Control Characteristic Analysis for Dynamic Controlled Atmosphere Storage," The Journal of Korean Institute of Communications and Information Sciences, vol. 46, no. 11, pp. 2064-2071, 11. 2021. (https://doi.org/10.7840/kics.2021.46.11.2064)